Start with measured prepared liquid#
Choose an output, measure the mixture after preparation, then enter its volume and the share of the intended active ingredient. Each item consumes total mixture; the Finisher does not create the active component. Keep the output grid clear.
This calculator uses a community analysis of 0.46D / Build 26337366. It has not been tested in-game by this site. Later patches, mods and hidden precision can change results.
From raw inputs to a checked batch#
Scan the starting materials and the liquid after each treatment. Bottles can bring impurities; the final mixture matters more than the recipe’s ideal output. Use a small batch while learning the sequence.
- Choose the product and reserve its inputs, a receiving container, power and output space.
- Blend solid inputs when needed. React on the Heating Plate using the product’s conditions below; observe the liquid temperature.
- Remove contaminants with the appropriate treatment. A Water Purifier is not a chemical-batch cleaner: it removes the non-water ingredients you are trying to keep.
- Evaporate remaining volatile liquid as needed, then scan again. Check active share and dryness separately.
- Fit the intended Finisher modules, package a test output and inspect its actual grade before committing the batch.
Seven Finisher products#
Sample sizes are total mixture per item. They are not minimum pure-active doses. Suggested contraband modifiers in the calculator need confirmation for your customer and permits.
Scroll sideways to see all columns.
| Product | Grading component | Sample | Base value |
|---|---|---|---|
| Caffeine PillSource 1Source 2 | Caffeine | 5 mL | 10 cr |
| Dream DustSource 1Source 2 | Dream Cap Extract | 2 mL | 18 cr |
| Nightmare DustSource 1Source 2 | Nightmare Extract | 4 mL | 36 cr |
| Zyanide PillSource 1Source 2 | Zyanide | 0.6 mL | 33 cr |
| Birth Control PillSource 1Source 2 | Contraceptive Hormones | 0.1 mL | 15 cr |
| Phanta PillSource 1Source 2 | Phanta | 0.5 mL | 12 cr |
| Nomore InjectorSource 1Source 2 | Nomore | 4 mL | 50 cr |
Purity grades and integer sampling#
Grades use unrounded active-component share. Whole-microlitre sampling and contamination replacement can shift a result near a threshold. The tool gives conservative purity bounds from your percentage reading; a grade range means the full component allocation is needed to narrow it.
Scroll sideways to see all columns.
Read the sale conditions and rounding alternative#
A quote applies the purity grade, then applicable market adjustments, then the final bargain adjustment. Difficulty retail markup depends on the customer accepting it. Revenue assumes the whole batch can sell under those conditions; it is not profit.
The code-analysis source describes integer midpoint-to-even rounding. Another public calculator uses even-multiple rounding. The tool exposes an alternative where they differ rather than treating the higher number as guaranteed. For example, a 10 cr Caffeine Pill at Lab Pure, Normal +15% and no other adjustment gives an unrounded 27.025 cr: integer rounding gives 27, while even-multiple rounding gives 28.
Check dryness before packaging#
The named community build accepts up to 100 µL of all evaporative components combined. Blank means this condition has not been checked; a high active purity alone does not prove dryness. When the test fails, the displayed quantity remains theoretical.
The independent evaporator helper uses actual volatile volume and a fixed Performance allowance, assuming uninterrupted power and no intervening reactions. It does not predict the resulting active purity. Measure again afterward.
Caffeine Pill#
Extract Caffeine from Coffee Bean Mush using the documented Alcohol or Water route, then prepare and measure the liquid. Their temperature requirements and yield caps differ; a yield cap is not the final purity of your whole mixture.
Measure Caffeine as a share of the prepared total mixture. One finished item samples 5 mL.
- Blend Coffee Beans if needed, then inspect the Coffee Bean Mush and existing Caffeine in the mixture.
- The Alcohol extraction branch needs at least 50°C and has an active-output cap of 75% of the mush processed in that update. The Water branch needs at least 80°C and caps at 12.5%. Solvent availability and processing order also matter.
- Remove remaining volatile liquids as needed. Measure the prepared volume and Caffeine share; each pill samples 5 mL of total mixture.
Dream Dust#
Prepare Dream Cap Extract from ordinary Dream Cap Mush and Alcohol. Heat can also degrade the material. Observe actual liquid temperature and measure after treatment before selecting the Dream Dust output.
Measure Dream Cap Extract as a share of the prepared total mixture. One finished item samples 2 mL.
- Blend ordinary Dream Caps into a container with room for the output; the edible variant has a different main component.
- Extraction needs Dream Cap Mush, Alcohol and at least 40°C. The documented 50% per-update active-yield cap requires the current Alcohol-to-mush ratio to be at least 5:1; it is not the final container purity.
- Monitor the actual temperature. Mush degradation begins above 50°C and Dream Cap Extract degradation above 60°C in the source model.
- Prepare and remeasure the liquid. Each Dream Dust samples 2 mL of total mixture.
Nightmare Dust#
Prepare Nightmare Extract from Nightmare Cap Mush and Alcohol. Monitor heat degradation instead of assuming that a hotter setting makes more extract. Measure the prepared mixture for this output.
Measure Nightmare Extract as a share of the prepared total mixture. One finished item samples 4 mL.
- Prepare Nightmare Cap Mush and Alcohol.
- The extraction branch requires at least 40°C and has the same per-update yield formula as Dream Cap extraction. The available solvent and current mush amount matter.
- Avoid overheating: Nightmare Extract and Nightmare Cap Mush begin degrading above 50°C in the source model.
- Prepare and measure the mixture. Each Nightmare Dust samples 4 mL.
Zyanide Pill#
Package an existing Zyanide mixture. Recovering composition from obtainable pills is documented; this output recipe does not establish a separate precursor synthesis. Dissolving a pill also transfers its fillers.
Measure Zyanide as a share of the prepared total mixture. One finished item samples 0.6 mL.
- Start from an obtainable Zyanide-containing item or mixture. Evidence Locker pills are one documented source.
- Dissolve or otherwise process the item into an owned liquid container; its other components transfer too. A factory pill is not evidence that every prepared mixture has the same volume or purity.
- Measure Zyanide share, remove volatile liquids as needed, then select Zyanide Pill. Each output samples 0.6 mL of total mixture.
Birth Control Pill#
Use an existing Contraceptive Hormone mixture. This is a packaging instruction, not a newly established synthesis route. The small sample makes integer allocation especially relevant near a grade boundary.
Measure Contraceptive Hormones as a share of the prepared total mixture. One finished item samples 0.1 mL.
- Use an existing Contraceptive Hormone mixture or recover the composition from an obtainable pill.
- Inspect the received mixture, including fillers. No separate precursor synthesis is established by the Finisher recipe.
- Check dryness and measure the hormone share. Each pill samples 0.1 mL; review the integer-allocation grade bounds.
Phanta Pill#
Prepare Phanta under the documented reagent and temperature conditions, then measure. The upper synthesis temperature is exclusive. The planner does not turn a published reaction yield cap into a guaranteed active amount.
Measure Phanta as a share of the prepared total mixture. One finished item samples 0.5 mL.
- The documented reaction requires N-Methylol Base greater than Stabilizing Agent, with Reducing Agent present.
- Keep measured liquid temperature at least 110°C and strictly below 130°C. The branch rate changes at 120°C, while Phanta degradation applies at 130°C and above.
- Active output is 10% of the amount processed by the synthesis branch, not 10% purity guaranteed for the container. Prepare, remove remaining volatile liquids and remeasure.
- Each Phanta Pill samples 0.5 mL of the prepared total mixture.
Nomore Injector#
Prepare Nomore from the documented reagents before finishing. Observe the measured temperature and solvent constraint. The required active component is Nomore; other similar item names are not interchangeable.
Measure Nomore as a share of the prepared total mixture. One finished item samples 4 mL.
- Use Dream Cap Extract, Reducing Agent and Lipobond Agent. The documented branch requires all three.
- Keep measured liquid temperature between 45°C and 55°C inclusive, and Alcohol at no more than 10% of the total. Lipobond amount affects the processing rate.
- The branch converts consumed extract/reducing reagent into Nomore and debris; its 60% active yield does not establish final container purity.
- Remove volatile liquids, including residual Lipobond Agent, as needed. Remeasure Nomore share; each injector samples 4 mL of total mixture.
Use each machine for its own preparation step#
The Blender helper scales supported raw ingredient components and shows the receiving-space check. It does not predict subsequent reactions. Entering multiple items as one combined weight can change rounding.
The Heating Plate helper shows target controls and heating-factor upgrades. These do not instantly set actual liquid temperature, and a heating-factor multiplier is not the same multiplier on the temperature rise.
Troubleshoot the stage that failed#
Scroll sideways to see all columns.
| Symptom | Check next |
|---|---|
| Little active ingredient after heatingSource 1Source 2 | Confirm the reagents and measured liquid temperature; hotter is not always better. |
| Finisher rejects an apparently pure batchSource | Check all evaporative components, not just the active percentage. |
| Output grade below the input readingSource | Check Finisher contamination and integer sampling near grade boundaries. |
| Evaporation estimate did not match the nightSource | Check power, Performance, actual volatile volume and any intervening reactions; remeasure. |
| Old guide says every final trace blocks packagingSource | Patch 1.0.0.5 fixed the residual 1 µL issue and dry-recipe handling of trace moisture. Do not diagnose solely from an old screenshot. |
Separate the Chemist hand-in from retail stock#
The Chemist start has a weekly Dream Dust delivery. The original player guide says the handler takes every Dream Dust vial on the counter and evaluates the delivered quantity and average purity. Put out only the vials you intend to hand over.
Reserve that delivery before choosing stock for retail or an active Exchange promotion. The calculator estimates a sale under the entered conditions; it does not validate the cartel quota, calculate its reputation outcome or predict a random Exchange reward.
